防火卷簾門(mén)的面積核算方式及裝置要求
防火卷簾門(mén)的面積核算方式及裝置要求
Calculation method and installation requirements for the area of fireproof rolling shutter doors
1、操控系統(tǒng)滿(mǎn)意一般鋼質(zhì)復(fù)合卷簾的操控要求。
1. The control system is satisfied with the control requirements of general steel composite roller blinds.
2、缺相主動(dòng)維護(hù)功用。防火卷簾門(mén)
2. Proactive maintenance function for phase deficiency. Fireproof rolling shutter door
3、無(wú)需噴淋維護(hù),下降了消防水源的用量。
3. No need for sprinkler maintenance, reducing the usage of fire water sources.
4、具有電源進(jìn)線(xiàn)相序主動(dòng)檢測(cè)。
4. It has active detection of power input phase sequence.
5、提供給消防操控中心門(mén)位狀況信號(hào)。
5. Provide door position status signals to the fire control center.
6、質(zhì)輕、卷曲功用好,占用空間小,啟閉靈敏,噪音小,系數(shù)更長(zhǎng)處。
6. Lightweight, good curling function, small space occupation, sensitive opening and closing, low noise, and higher safety factor.
7、選用雙軌雙簾結(jié)構(gòu)規(guī)劃、簾面選用多層無(wú)機(jī)耐火隔熱資料構(gòu)成,具有優(yōu)異的防煙、防火功用,經(jīng)1200℃耐火試驗(yàn)背火面均勻溫升不超越140℃, 高溫升不超越180℃,。
7. The double track double curtain structure is selected for planning, and the curtain surface is composed of multiple layers of inorganic fire-resistant and heat-insulating materials, which have excellent smoke and fire prevention functions. After 1200 ℃ fire resistance test, the uniform temperature rise of the back fire surface does not exceed 140 ℃, and the high temperature rise does not exceed 180 ℃,.
8、抗拉強(qiáng)度大,抗腐蝕、濕潤(rùn)功用強(qiáng)。
8. High tensile strength, strong corrosion resistance and moisture resistance.
防火卷簾門(mén)裝置要求及面積核算
Requirements and area calculation for fireproof rolling shutter door installation
一、防火卷簾門(mén)裝置要求:
1、 Requirements for the installation of fireproof rolling shutter doors:
1、卷簾門(mén)裝置好后,裝置吊頂,吊頂邊緣應(yīng)離簾板50mm,避免磨擦;
1. After the installation of the rolling shutter door, the suspended ceiling should be installed, and the edge of the suspended ceiling should be 50mm away from the curtain board to avoid friction;
2、裝置卷簾門(mén)的洞口上部不得設(shè)有通風(fēng)管、水管等;
2. The upper part of the opening of the rolling shutter door shall not be equipped with ventilation pipes, water pipes, etc;
3、電源線(xiàn)路(三相五線(xiàn)和消防中控信號(hào)線(xiàn))由用戶(hù)鋪設(shè)到卷門(mén)機(jī)旁的電氣操控箱邊;
3. The power lines (three-phase five wire and fire control signal line) are laid by the user to the electrical control box next to the rolling door machine;
4、依據(jù)消防管理
4. According to fire management
5、調(diào)試及運(yùn)用時(shí),禁止底部站人。電器設(shè)備不得私行拆搬。
5. During debugging and application, it is prohibited to stand at the bottom. Electrical equipment shall not be dismantled or moved privately.
閱讀/ Recommended reading
- 車(chē)庫(kù)卷簾門(mén)彈簧問(wèn)題的維修指南 2025-02-22
- 翻板車(chē)庫(kù)門(mén)和卷簾車(chē)庫(kù)門(mén)有什么不同 2025-02-11
- 剖析翻板車(chē)庫(kù)門(mén)和卷簾車(chē)庫(kù)門(mén)有什么不同點(diǎn) 2025-02-01
- 防火卷簾門(mén)的面積核算方式及裝置要求 2025-02-14
- 濟(jì)南卷簾門(mén)限位器壞了還能修理嗎? 2025-02-03
- 每一扇卷簾門(mén),都是品質(zhì)與工藝的結(jié)晶 2025-01-27
- 電動(dòng)卷簾門(mén)限位調(diào)整需要注意什么 2025-01-07
- 濟(jì)南卷簾門(mén)的工作原理及安裝維修 2024-12-18
卷簾門(mén)遙控器的配對(duì)方法因類(lèi)型不同而有所差異,以下是常見(jiàn)的幾種配對(duì)方式:The pairing methods for remote control of rolling shutt...